CVE DatabaseCVE-2026-15410
한국어 권고문 →
CVE-2026-154107.2/HIGHCISA KEVCWE-94

SonicWall SMA1000 Appliance Management Console (AMC) Remote Code Execution and OS Command Injection (CVE-2026-15410)

Affected Vendors
sonicwall
Affected Components
sma1000, appliance management console
Published Date
2026-07-14

Executive & SecOps Summary

SECOPS ASSESSMENT
Affected Scope

SonicWall SMA1000 appliances utilizing the Appliance Management Console (AMC)

Impact

An authenticated remote attacker with administrative privileges can execute arbitrary OS commands under specific conditions, potentially leading to full system compromise

Mitigation

Immediately apply the latest firmware patches provided by SonicWall and restrict external access to the management console

Affected Products & Version Scope

SonicWall SMA1000 Series appliances running vulnerable versions of the Appliance Management Console (AMC)

Remediation & Live Workaround Commands

PATCH & WORKAROUND

1. Apply Official Security Patches

Immediately upgrade to the patched firmware versions recommended in the official SonicWall security advisory.

2. Temporary Mitigations

If immediate patching is not feasible, implement the following defensive measures:

  • Restrict Management Access: Disable public internet access to the AMC port (typically TCP 8443). Restrict access exclusively to trusted internal management networks or dedicated admin VPNs.
  • Enforce Multi-Factor Authentication (MFA): Mandate MFA for all administrative accounts accessing the AMC to prevent unauthorized credential-based access.
  • Audit and Monitor Logs: Closely monitor AMC web server logs and system audit logs for anomalous administrative activities or signs of command injection attempts.
Recommended Security Control & Mitigation Partner
NordLayer / Zero-Trust Network Access
As this vulnerability is actively exploited in the wild (CISA KEV), immediately restrict external access to the SMA1000 AMC and apply the vendor patches.

Stop Exposing VPN Ports to the Internet — Switch to Zero-Trust Access

Eliminate public-facing VPN concentrators and firewall management ports with identity-first Zero-Trust Network Access.

90% Attack Surface Reduction · Hardware-Free

Technical Root Cause & Exploitation Mechanics

CVE-2026-15410 is a post-authentication improper control of generation of code ('Code Injection', CWE-94) vulnerability identified in the SonicWall SMA1000 Appliance Management Console (AMC).

The root cause lies in the insufficient validation and sanitization of user-supplied input within the AMC administrative interface. An attacker who has successfully authenticated with administrative privileges can inject malicious payloads into specific configuration parameters, which are subsequently executed as system-level OS commands. Although the vulnerability requires prior authentication, it poses a severe threat (CVSS 7.2) and has been added to the CISA Known Exploited Vulnerabilities (KEV) catalog due to active exploitation in the wild.

Successful exploitation allows attackers to run arbitrary commands with elevated privileges on the underlying operating system of the SMA1000 appliance, enabling lateral movement, credential harvesting, and interception of VPN traffic.

Official Vendor Advisories & References

NVD Original English Description

Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute arbitrary OS commands.

SecOps Advisory Dispatch & RSS Feed

Subscribe to Daily Vulnerability Briefings & KEV Alerts

Concise morning briefings for SecOps, DevSecOps, and SRE teams covering newly exploited CVEs and mitigation priorities.

Slack / Teams / RSS Feed: